#  Deep convection simulation using MITgcm
#  PIs: Takamitsu Ito and Anna Bracco
#     data version 28 Jun 2017
#        All 44 MATLAB .mat files listed below with links to download individual files.
#        Or download a ZIP file containing all .mat files: model_output.zip (50 MB)
=========================
experiment_name                                   experiment_type              comment                                                                                            filesize    file_download_link                                                                                                                                                      
-------------------------
pro_in_O2_z41_step_120d_dif_4                     Dissolved oxygen profile     cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 5 m s-1; without bubble injection      105K        pro_in_O2_z41_step_120d_dif_4.mat                                      
pro_in_O2_z41_step_120d_dif_4_15c                 Dissolved oxygen profile     cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 5 m s-1; without bubble injection     105K        pro_in_O2_z41_step_120d_dif_4_15c.mat                              
pro_in_O2_z41_step_120d_dif_4_15c_B               Dissolved oxygen profile     cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 5 m s-1; with bubble injection        105K        pro_in_O2_z41_step_120d_dif_4_15c_B.mat                          
pro_in_O2_z41_step_120d_dif_4_30c                 Dissolved oxygen profile     cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 5 m s-1; without bubble injection      105K        pro_in_O2_z41_step_120d_dif_4_30c.mat                              
pro_in_O2_z41_step_120d_dif_4_30c_B               Dissolved oxygen profile     cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 5 m s-1; with bubble injection         105K        pro_in_O2_z41_step_120d_dif_4_30c_B.mat                          
pro_in_O2_z41_step_120d_dif_4_4900611_relax       Dissolved oxygen profile     validation run using Argo data (Argo ID: 4900611); with bubble injection                           210K        pro_in_O2_z41_step_120d_dif_4_4900611_relax.mat          
pro_in_O2_z41_step_120d_dif_4_4900611_relax_nB    Dissolved oxygen profile     validation run using Argo data (Argo ID: 4900611); without bubble injection                        209K        pro_in_O2_z41_step_120d_dif_4_4900611_relax_nB.mat    
pro_in_O2_z41_step_120d_dif_4_6c                  Dissolved oxygen profile     cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 5 m s-1; without bubble injection      105K        pro_in_O2_z41_step_120d_dif_4_6c.mat                                
pro_in_O2_z41_step_120d_dif_4_6c_B                Dissolved oxygen profile     cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 5 m s-1; with bubble injection         106K        pro_in_O2_z41_step_120d_dif_4_6c_B.mat                            
pro_in_O2_z41_step_120d_dif_4_B                   Dissolved oxygen profile     cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 5 m s-1; with bubble injection         105K        pro_in_O2_z41_step_120d_dif_4_B.mat                                  
pro_in_O2_z41_step_120d_dif_4_wind15              Dissolved oxygen profile     cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 15 m s-1; without bubble injection     105K        pro_in_O2_z41_step_120d_dif_4_wind15.mat                        
pro_in_O2_z41_step_120d_dif_4_wind15_15c          Dissolved oxygen profile     cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 15 m s-1; without bubble injection    105K        pro_in_O2_z41_step_120d_dif_4_wind15_15c.mat                
pro_in_O2_z41_step_120d_dif_4_wind15_15c_B        Dissolved oxygen profile     cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 15 m s-1; with bubble injection       105K        pro_in_O2_z41_step_120d_dif_4_wind15_15c_B.mat            
pro_in_O2_z41_step_120d_dif_4_wind15_30c          Dissolved oxygen profile     cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; without bubble injection     105K        pro_in_O2_z41_step_120d_dif_4_wind15_30c.mat                
pro_in_O2_z41_step_120d_dif_4_wind15_30c_B        Dissolved oxygen profile     cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        105K        pro_in_O2_z41_step_120d_dif_4_wind15_30c_B.mat            
pro_in_O2_z41_step_120d_dif_4_wind15_6c           Dissolved oxygen profile     cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 15 m s-1; without bubble injection     105K        pro_in_O2_z41_step_120d_dif_4_wind15_6c.mat                  
pro_in_O2_z41_step_120d_dif_4_wind15_6c_B         Dissolved oxygen profile     cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 15 m s-1; with bubble injection        106K        pro_in_O2_z41_step_120d_dif_4_wind15_6c_B.mat              
pro_in_O2_z41_step_120d_dif_4_wind15_B            Dissolved oxygen profile     cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 15 m s-1; with bubble injection        105K        pro_in_O2_z41_step_120d_dif_4_wind15_B.mat                    
pro_in_S_z41_step_120d_dif_4_4900611_relax        Salinity profile             validation run using Argo data (Argo ID: 4900611); with bubble injection                           156K        pro_in_S_z41_step_120d_dif_4_4900611_relax.mat            
pro_in_S_z41_step_120d_dif_4_4900611_relax_nB     Salinity profile             validation run using Argo data (Argo ID: 4900611); without bubble injection                        156K        pro_in_S_z41_step_120d_dif_4_4900611_relax_nB.mat      
pro_in_T_z41_step_120d_dif_4                      Temperature profile          cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 5 m s-1; without bubble injection      81K         pro_in_T_z41_step_120d_dif_4.mat                                        
pro_in_T_z41_step_120d_dif_4_15c                  Temperature profile          cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 5 m s-1; without bubble injection     81K         pro_in_T_z41_step_120d_dif_4_15c.mat                                
pro_in_T_z41_step_120d_dif_4_15c_B                Temperature profile          cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 5 m s-1; with bubble injection        81K         pro_in_T_z41_step_120d_dif_4_15c_B.mat                            
pro_in_T_z41_step_120d_dif_4_30c                  Temperature profile          cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 5 m s-1; without bubble injection      81K         pro_in_T_z41_step_120d_dif_4_30c.mat                                
pro_in_T_z41_step_120d_dif_4_30c_B                Temperature profile          cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 5 m s-1; with bubble injection         81K         pro_in_T_z41_step_120d_dif_4_30c_B.mat                            
pro_in_T_z41_step_120d_dif_4_4900611_relax        Temperature profile          validation run using Argo data (Argo ID: 4900611); with bubble injection                           164K        pro_in_T_z41_step_120d_dif_4_4900611_relax.mat            
pro_in_T_z41_step_120d_dif_4_4900611_relax_nB     Temperature profile          validation run using Argo data (Argo ID: 4900611); without bubble injection                        164K        pro_in_T_z41_step_120d_dif_4_4900611_relax_nB.mat      
pro_in_T_z41_step_120d_dif_4_6c                   Temperature profile          cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 5 m s-1; without bubble injection      81K         pro_in_T_z41_step_120d_dif_4_6c.mat                                  
pro_in_T_z41_step_120d_dif_4_6c_B                 Temperature profile          cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 5 m s-1; with bubble injection         81K         pro_in_T_z41_step_120d_dif_4_6c_B.mat                              
pro_in_T_z41_step_120d_dif_4_B                    Temperature profile          cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 5 m s-1; with bubble injection         81K         pro_in_T_z41_step_120d_dif_4_B.mat                                    
pro_in_T_z41_step_120d_dif_4_wind15               Temperature profile          cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 15 m s-1; without bubble injection     81K         pro_in_T_z41_step_120d_dif_4_wind15.mat                          
pro_in_T_z41_step_120d_dif_4_wind15_15c           Temperature profile          cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 15 m s-1; without bubble injection    81K         pro_in_T_z41_step_120d_dif_4_wind15_15c.mat                  
pro_in_T_z41_step_120d_dif_4_wind15_15c_B         Temperature profile          cooling duration: 15 days; heat flux: 1600 W/m2; wind speed: 15 m s-1; with bubble injection       81K         pro_in_T_z41_step_120d_dif_4_wind15_15c_B.mat              
pro_in_T_z41_step_120d_dif_4_wind15_30c           Temperature profile          cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; without bubble injection     81K         pro_in_T_z41_step_120d_dif_4_wind15_30c.mat                  
pro_in_T_z41_step_120d_dif_4_wind15_30c_B         Temperature profile          cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        81K         pro_in_T_z41_step_120d_dif_4_wind15_30c_B.mat              
pro_in_T_z41_step_120d_dif_4_wind15_6c            Temperature profile          cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 15 m s-1; without bubble injection     81K         pro_in_T_z41_step_120d_dif_4_wind15_6c.mat                    
pro_in_T_z41_step_120d_dif_4_wind15_6c_B          Temperature profile          cooling duration: 6 days; heat flux: 4000 W/m2; wind speed: 15 m s-1; with bubble injection        81K         pro_in_T_z41_step_120d_dif_4_wind15_6c_B.mat                
pro_in_T_z41_step_120d_dif_4_wind15_B             Temperature profile          cooling duration: 60 days; heat flux: 400 W/m2; wind speed: 15 m s-1; with bubble injection        81K         pro_in_T_z41_step_120d_dif_4_wind15_B.mat                      
XY_O2_z41_step_120d_dif_4_wind15_30c_B_z1y66      Surface oxygen               cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        4.4M        XY_O2_z41_step_120d_dif_4_wind15_30c_B_z1y66.mat        
XY_T_z41_step_120d_dif_4_wind15_30c_B_z1y66       Surface temperature          cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        4.9M        XY_T_z41_step_120d_dif_4_wind15_30c_B_z1y66.mat          
XY_UVW_z41_step_120d_dif_4_wind15_30c_B_z22y66    Velocity at 100 m            cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        20M         XY_UVW_z41_step_120d_dif_4_wind15_30c_B_z22y66.mat    
XZ_O2_z41_step_120d_dif_4_wind15_30c_B_z1y66      Dissolved oxygen transect    cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        5.4M        XZ_O2_z41_step_120d_dif_4_wind15_30c_B_z1y66.mat        
XZ_T_z41_step_120d_dif_4_wind15_30c_B_z1y66       Temperature transect         cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        5.4M        XZ_T_z41_step_120d_dif_4_wind15_30c_B_z1y66.mat          
XZ_UVW_z41_step_120d_dif_4_wind15_30c_B_z22y66    Velocity transect            cooling duration: 30 days; heat flux: 800 W/m2; wind speed: 15 m s-1; with bubble injection        6.2M        XZ_UVW_z41_step_120d_dif_4_wind15_30c_B_z22y66.mat